Use our search engine

Facilities

The plant is designed to have a maximum treatment capacity of 240 m3/day of potable water operating continuously (24 hours/day). It has been operated with a flow rate of 6.25 m3/h.

The treatment line has the following processes:

  • Intake by self-cleaning filter and raw water pumping
  • Pre-oxidation:
    • O3 (Pre-Ozone)
    • Cl2
    • ClO2
    • Potassium permanganate
  • Coagulation with pH adjustment
  • In-line flocculation and dosing of reagents: flocculant and possibility of oxidation at this stage (potassium permanganate, Cl2, ClO2, CAP).
  • Decanting (Accentrifloc type decanter)
  • Sand Filtration
  • Filtered water tank and filter washing and pumping to advanced oxidation/oxidation stage.
  • pH adjustment (using sodium hydroxide) and advanced oxidation/oxidation:
    • O3
    • O3/H2O2
    • UV
  • Active Carbon Filtration. 2 different AC filters are operated alternatively
  • Treated Water Tank
  • Final disinfection with Cl2 (disinfection with ClO2 has been discarded for the time being).
  • Treated water tank with 10-minute retention time
  • Plant outlet tank with 12-hour retention time